Lift Manager v1.0

 

Version Info

  • Add 'Priority Index' configuration parameter.
  • Add status parameters to show the actual load ratio and Plunger Lift control state.

Group 'Plunger Coordination'

Coordinate plunger lift applications

This is a configuration group that has 139 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Enable Plunger CoordinationenPlCoord1114112booliTruemin:False;max:True;Global enable for plunger lift coordination features. When this value is true to the application will coordinate plunger lift applications and prevent more than the configured number of applications from lifting at the same time. When false, this app will not manage any plunger lift applications.
Coordination MetricplCoordMetric1114113i32i0:Priority0:Priority; 1:High Load Ratio; 2:Low Load Ratio; 3:Round Robin; Select the metric to use to determine which wells are allowed to flow first. 'Priority' always selects the well with the lowest value of 'Priority Index'. 'High Load Ratio' selects the well with the highest load ratio. 'Low Load Ratio' selects the well with the lowest load ratio. 'Round Robin' selects the next enabled well where wells are sorted from the lowest value of 'Priority Index' to the highest.
Max Lift CountmaxLiftCount1114120i16i1min:1;max:16;The number of wells that can simultaneously lift at the same time.
Enable Well Coordination 01enWellCoord_0011116262booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 01priorityIdx_0011116270i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 01locationRemote_0011116263booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 01prefixPl_0011116264stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 01controlStateTgNm_0011116265stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 01inhibitOpenTgNm_0011116266stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 01loadRatioTgNm_0011116267stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 01execCountTgNm_0011116269stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 02enWellCoord_0021116362booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 02priorityIdx_0021116370i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 02locationRemote_0021116363booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 02prefixPl_0021116364stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 02controlStateTgNm_0021116365stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 02inhibitOpenTgNm_0021116366stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 02loadRatioTgNm_0021116367stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 02execCountTgNm_0021116369stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 03enWellCoord_0031116462booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 03priorityIdx_0031116470i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 03locationRemote_0031116463booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 03prefixPl_0031116464stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 03controlStateTgNm_0031116465stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 03inhibitOpenTgNm_0031116466stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 03loadRatioTgNm_0031116467stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 03execCountTgNm_0031116469stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 04enWellCoord_0041116562booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 04priorityIdx_0041116570i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 04locationRemote_0041116563booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 04prefixPl_0041116564stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 04controlStateTgNm_0041116565stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 04inhibitOpenTgNm_0041116566stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 04loadRatioTgNm_0041116567stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 04execCountTgNm_0041116569stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 05enWellCoord_0051116662booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 05priorityIdx_0051116670i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 05locationRemote_0051116663booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 05prefixPl_0051116664stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 05controlStateTgNm_0051116665stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 05inhibitOpenTgNm_0051116666stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 05loadRatioTgNm_0051116667stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 05execCountTgNm_0051116669stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 06enWellCoord_0061116762booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 06priorityIdx_0061116770i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 06locationRemote_0061116763booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 06prefixPl_0061116764stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 06controlStateTgNm_0061116765stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 06inhibitOpenTgNm_0061116766stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 06loadRatioTgNm_0061116767stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 06execCountTgNm_0061116769stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 07enWellCoord_0071116862booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 07priorityIdx_0071116870i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 07locationRemote_0071116863booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 07prefixPl_0071116864stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 07controlStateTgNm_0071116865stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 07inhibitOpenTgNm_0071116866stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 07loadRatioTgNm_0071116867stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 07execCountTgNm_0071116869stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 08enWellCoord_0081116962booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 08priorityIdx_0081116970i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 08locationRemote_0081116963booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 08prefixPl_0081116964stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 08controlStateTgNm_0081116965stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 08inhibitOpenTgNm_0081116966stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 08loadRatioTgNm_0081116967stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 08execCountTgNm_0081116969stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 09enWellCoord_0091117062booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 09priorityIdx_0091117070i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 09locationRemote_0091117063booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 09prefixPl_0091117064stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 09controlStateTgNm_0091117065stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 09inhibitOpenTgNm_0091117066stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 09loadRatioTgNm_0091117067stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 09execCountTgNm_0091117069stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 10enWellCoord_0101117162booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 10priorityIdx_0101117170i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 10locationRemote_0101117163booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 10prefixPl_0101117164stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 10controlStateTgNm_0101117165stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 10inhibitOpenTgNm_0101117166stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 10loadRatioTgNm_0101117167stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 10execCountTgNm_0101117169stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 11enWellCoord_0111117262booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 11priorityIdx_0111117270i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 11locationRemote_0111117263booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 11prefixPl_0111117264stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 11controlStateTgNm_0111117265stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 11inhibitOpenTgNm_0111117266stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 11loadRatioTgNm_0111117267stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 11execCountTgNm_0111117269stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 12enWellCoord_0121117362booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 12priorityIdx_0121117370i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 12locationRemote_0121117363booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 12prefixPl_0121117364stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 12controlStateTgNm_0121117365stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 12inhibitOpenTgNm_0121117366stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 12loadRatioTgNm_0121117367stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 12execCountTgNm_0121117369stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 13enWellCoord_0131117462booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 13priorityIdx_0131117470i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 13locationRemote_0131117463booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 13prefixPl_0131117464stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 13controlStateTgNm_0131117465stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 13inhibitOpenTgNm_0131117466stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 13loadRatioTgNm_0131117467stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 13execCountTgNm_0131117469stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 14enWellCoord_0141117562booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 14priorityIdx_0141117570i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 14locationRemote_0141117563booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 14prefixPl_0141117564stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 14controlStateTgNm_0141117565stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 14inhibitOpenTgNm_0141117566stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 14loadRatioTgNm_0141117567stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 14execCountTgNm_0141117569stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 15enWellCoord_0151117662booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 15priorityIdx_0151117670i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 15locationRemote_0151117663booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 15prefixPl_0151117664stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 15controlStateTgNm_0151117665stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 15inhibitOpenTgNm_0151117666stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 15loadRatioTgNm_0151117667stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 15execCountTgNm_0151117669stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.
Enable Well Coordination 16enWellCoord_0161117762booliFalsemin:False;max:True;Whether to include this configuration in the group of plunger lift applications that are coordinated.
Priority Index 16priorityIdx_0161117770i16i100min:0;max:32767;Set the priority of this well.
Remote Well Location 16locationRemote_0161117763booliFalsemin:False;max:True;Set this value when the plunger lift application to be coordinated exists on a different controller or in a different PLC Shift runtime. When set, this application will coordinate the plunger lift application through the use of tags that are mapped through the PLC. When false, this application will coordinate the plunger lift application through an internal mechanism and the application must be in the same PLC Shift runtime.
Plunger Lift Application Prefix 16prefixPl_0161117764stringiPL01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The configured tag name prefix for the plunger lift application.
Control State Tag Name 16controlStateTgNm_0161117765stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Control State' status parameter for the plunger lift application.
Inhibit Open Valve Tag Name 16inhibitOpenTgNm_0161117766stringboolominChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Inhibit Open Valve' control parameter for the plunger lift application.
Load Ratio Tag Name 16loadRatioTgNm_0161117767stringdoubleiminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Load Ratio' status parameter for the plunger lift application.
Exec Count Tag Name 16execCountTgNm_0161117769stringi32iminChars:0;maxChars:32; spaces:False; lettersNumbersOnly:True;The tag name of the 'Execution Count' status parameter for the plunger lift application.

Group 'Lift Override'

Control settings to override configured behavior

This is a control group that has 16 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Override Inhibit 01overrideInhibit018454144boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 01' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 02overrideInhibit028454145boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 02' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 03overrideInhibit038454146boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 03' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 04overrideInhibit048454147boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 04' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 05overrideInhibit058454148boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 05' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 06overrideInhibit068454149boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 06' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 07overrideInhibit078454150boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 07' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 08overrideInhibit088454151boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 08' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 09overrideInhibit098454152boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 09' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 10overrideInhibit108454153boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 10' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 11overrideInhibit118454154boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 11' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 12overrideInhibit128454155boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 12' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 13overrideInhibit138454156boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 13' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 14overrideInhibit148454157boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 14' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 15overrideInhibit158454158boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 15' to 'false'. This allows the well to flow without any coordination.
Override Inhibit 16overrideInhibit168454159boolioFalsemin:False;max:True;Set this value to override this application and force 'Inhibit Open Valve' for 'PL App 16' to 'false'. This allows the well to flow without any coordination.

Group 'Configuration Group Status'

Parameters in this group indicate the status of the associated configuration group

This is a status group that has 1 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Plunger Coordination Group Configuration InvalidplCoordGrpVld5373952booloIndicates whether the configuration of the Plunger Coordination group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration

Group 'Plunger Status'

Status information for plunger lift applications

This is a status group that has 122 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Lifting CountliftingCount5439488i16oThe number of wells that are actively lifting.
Inhibit CountinhibitCount5439489i16oThe number of wells that are prevented from open their sales valve.
Flowing CountflowingCount5439490i16oThe number of wells where the sales valve is open and the well is flowing.
Coordination Is Enabled 01wellCoordEn_0015441639booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 01wellInputsBad_0015441643booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 01wellIsLifting_0015441640booloWhether this well is actively lifting.
Well Is Inhibited 01wellIsInhibited_0015441641booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 01wellIsFlowing_0015441642booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 01wellLdRatio_0015441644doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 01welCntrlState_0015441645i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 02wellCoordEn_0025441739booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 02wellInputsBad_0025441743booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 02wellIsLifting_0025441740booloWhether this well is actively lifting.
Well Is Inhibited 02wellIsInhibited_0025441741booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 02wellIsFlowing_0025441742booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 02wellLdRatio_0025441744doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 02welCntrlState_0025441745i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 03wellCoordEn_0035441839booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 03wellInputsBad_0035441843booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 03wellIsLifting_0035441840booloWhether this well is actively lifting.
Well Is Inhibited 03wellIsInhibited_0035441841booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 03wellIsFlowing_0035441842booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 03wellLdRatio_0035441844doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 03welCntrlState_0035441845i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 04wellCoordEn_0045441939booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 04wellInputsBad_0045441943booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 04wellIsLifting_0045441940booloWhether this well is actively lifting.
Well Is Inhibited 04wellIsInhibited_0045441941booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 04wellIsFlowing_0045441942booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 04wellLdRatio_0045441944doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 04welCntrlState_0045441945i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 05wellCoordEn_0055442039booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 05wellInputsBad_0055442043booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 05wellIsLifting_0055442040booloWhether this well is actively lifting.
Well Is Inhibited 05wellIsInhibited_0055442041booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 05wellIsFlowing_0055442042booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 05wellLdRatio_0055442044doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 05welCntrlState_0055442045i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 06wellCoordEn_0065442139booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 06wellInputsBad_0065442143booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 06wellIsLifting_0065442140booloWhether this well is actively lifting.
Well Is Inhibited 06wellIsInhibited_0065442141booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 06wellIsFlowing_0065442142booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 06wellLdRatio_0065442144doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 06welCntrlState_0065442145i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 07wellCoordEn_0075442239booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 07wellInputsBad_0075442243booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 07wellIsLifting_0075442240booloWhether this well is actively lifting.
Well Is Inhibited 07wellIsInhibited_0075442241booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 07wellIsFlowing_0075442242booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 07wellLdRatio_0075442244doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 07welCntrlState_0075442245i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 08wellCoordEn_0085442339booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 08wellInputsBad_0085442343booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 08wellIsLifting_0085442340booloWhether this well is actively lifting.
Well Is Inhibited 08wellIsInhibited_0085442341booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 08wellIsFlowing_0085442342booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 08wellLdRatio_0085442344doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 08welCntrlState_0085442345i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 09wellCoordEn_0095442439booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 09wellInputsBad_0095442443booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 09wellIsLifting_0095442440booloWhether this well is actively lifting.
Well Is Inhibited 09wellIsInhibited_0095442441booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 09wellIsFlowing_0095442442booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 09wellLdRatio_0095442444doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 09welCntrlState_0095442445i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 10wellCoordEn_0105442539booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 10wellInputsBad_0105442543booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 10wellIsLifting_0105442540booloWhether this well is actively lifting.
Well Is Inhibited 10wellIsInhibited_0105442541booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 10wellIsFlowing_0105442542booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 10wellLdRatio_0105442544doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 10welCntrlState_0105442545i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 11wellCoordEn_0115442639booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 11wellInputsBad_0115442643booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 11wellIsLifting_0115442640booloWhether this well is actively lifting.
Well Is Inhibited 11wellIsInhibited_0115442641booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 11wellIsFlowing_0115442642booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 11wellLdRatio_0115442644doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 11welCntrlState_0115442645i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 12wellCoordEn_0125442739booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 12wellInputsBad_0125442743booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 12wellIsLifting_0125442740booloWhether this well is actively lifting.
Well Is Inhibited 12wellIsInhibited_0125442741booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 12wellIsFlowing_0125442742booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 12wellLdRatio_0125442744doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 12welCntrlState_0125442745i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 13wellCoordEn_0135442839booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 13wellInputsBad_0135442843booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 13wellIsLifting_0135442840booloWhether this well is actively lifting.
Well Is Inhibited 13wellIsInhibited_0135442841booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 13wellIsFlowing_0135442842booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 13wellLdRatio_0135442844doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 13welCntrlState_0135442845i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 14wellCoordEn_0145442939booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 14wellInputsBad_0145442943booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 14wellIsLifting_0145442940booloWhether this well is actively lifting.
Well Is Inhibited 14wellIsInhibited_0145442941booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 14wellIsFlowing_0145442942booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 14wellLdRatio_0145442944doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 14welCntrlState_0145442945i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 15wellCoordEn_0155443039booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 15wellInputsBad_0155443043booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 15wellIsLifting_0155443040booloWhether this well is actively lifting.
Well Is Inhibited 15wellIsInhibited_0155443041booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 15wellIsFlowing_0155443042booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 15wellLdRatio_0155443044doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 15welCntrlState_0155443045i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.
Coordination Is Enabled 16wellCoordEn_0165443139booloWhether this application is enabled and included in the coordination group.
Well Inputs Bad 16wellInputsBad_0165443143booloWhether the inputs to this well are bad. Bad inputs typically indicate a configuration issue or communication issue with the Lift Manager application and the Plunger Lift application.
Well Is Lifting 16wellIsLifting_0165443140booloWhether this well is actively lifting.
Well Is Inhibited 16wellIsInhibited_0165443141booloWhether this well is prevented from opening its sales valve.
Well Is Flowing 16wellIsFlowing_0165443142booloWhether this well has its sales valve open and is flowing.
Well Load Ratio 16wellLdRatio_0165443144doubleo1:percent;1:percent; The load ratio for this well.
Well Control State 16welCntrlState_0165443145i32o0:Initialize0:Initialize; 1:Waiting For Flow; 2:Waiting For Plunger Arrival; 3:After Flow Delay; 4:Waiting to Shut In; 5:After Shut In Delay; 6:Manual Override; 7:Protection Enabled; 8:Paused; 9:End of Cycle; 10:Inhibit Open; The control state for this plunger lift application.