Well Test v1.2

 

Version Info

  • Add 'End Purge' command.

Group 'Flow Runs'

Configure information about the flow run apps.

This is a configuration group that has 6 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Enable GasenGas1114115booliTruemin:False;max:True;Whether to enable a gas run for this well test application. This is a global enable for gas functionality in the app. When not selected, this well test app will not attempt to read or write any data from the gas flow run.
Gas App Tag Name PrefixprefixGas1114116stringiGF01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The tag name prefix for the gas flow application. The well test application needs this information to be able to read and write tags from the gas flow app.
Enable LiquidenLiquid1114117booliTruemin:False;max:True;Whether to enable a liquid run for this well test application. This is a global enable for liquid functionality in the app. When not selected, this well test app will not attempt to read or write any data from the liquid flow run.
Liquid App Tag Name PrefixprefixLiquid1114118stringiLF01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The tag name prefix for the liquid flow application. The well test application needs this information to be able to read and write tags from the liquid flow app.
Enable WaterenWater1114119booliTruemin:False;max:True;Whether to enable a water run for this well test application. This is a global enable for water functionality in the app. When not selected, this well test app will not attempt to read or write any data from the water flow run.
Water App Tag Name PrefixprefixWater1114120stringiWF01_minChars:2;maxChars:12; spaces:False; lettersNumbersOnly:True;The tag name prefix for the water flow application. The well test application needs this information to be able to read and write tags from the water flow app.

Group 'Gas Config'

Configure gas products.

This is a configuration group that has 441 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Methane 01fractionMethane_0011181796doublei1min:0.0;max:1.0;The fraction of methane.
Nitrogen 01fractionNitrogen_0011181797doubleimin:0.0;max:1.0;The fraction of nitrogen.
Carbon Dioxide 01fractionCarbonDi_0011181798doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
Ethane 01fractionEthane_0011181799doubleimin:0.0;max:1.0;The fraction of ethane.
Propane 01fractionPropane_0011181800doubleimin:0.0;max:1.0;The fraction of propane.
i-Butane 01fractionIbutane_0011181806doubleimin:0.0;max:1.0;The fraction of i-Butane.
n-Butane 01fractionNbutane_0011181807doubleimin:0.0;max:1.0;The fraction of n-Butane.
i-Pentane 01fractionIpentane_0011181808doubleimin:0.0;max:1.0;The fraction of i-Pentane.
n-Pentane 01fractionNpentane_0011181809doubleimin:0.0;max:1.0;The fraction of n-Pentane.
n-Hexane 01fractionNhexane_0011181810doubleimin:0.0;max:1.0;The fraction of n-Hexane.
n-Heptane 01fractionNheptane_0011181811doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 02fractionMethane_0021181896doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 01fractionNoctane_0011181812doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 02fractionNitrogen_0021181897doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 01fractionNnonane_0011181813doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 02fractionCarbonDi_0021181898doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 01fractionNdecane_0011181814doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 02fractionEthane_0021181899doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 01fractionHydrogen_0011181803doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 02fractionPropane_0021181900doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 01fractionOxygen_0011181805doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 02fractionIbutane_0021181906doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 01fractionCarbonMo_0011181804doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 02fractionNbutane_0021181907doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 01fractionWater_0011181801doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 02fractionIpentane_0021181908doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 01fractionH2s_0011181802doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 02fractionNpentane_0021181909doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 01fractionHelium_0011181815doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 02fractionNhexane_0021181910doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 01fractionArgon_0011181816doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 02fractionNheptane_0021181911doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 03fractionMethane_0031181996doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 02fractionNoctane_0021181912doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 03fractionNitrogen_0031181997doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 02fractionNnonane_0021181913doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 03fractionCarbonDi_0031181998doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 02fractionNdecane_0021181914doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 03fractionEthane_0031181999doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 02fractionHydrogen_0021181903doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 03fractionPropane_0031182000doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 02fractionOxygen_0021181905doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 03fractionIbutane_0031182006doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 02fractionCarbonMo_0021181904doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 03fractionNbutane_0031182007doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 02fractionWater_0021181901doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 03fractionIpentane_0031182008doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 02fractionH2s_0021181902doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 03fractionNpentane_0031182009doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 02fractionHelium_0021181915doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 03fractionNhexane_0031182010doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 02fractionArgon_0021181916doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 03fractionNheptane_0031182011doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 04fractionMethane_0041182096doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 03fractionNoctane_0031182012doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 04fractionNitrogen_0041182097doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 03fractionNnonane_0031182013doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 04fractionCarbonDi_0041182098doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 03fractionNdecane_0031182014doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 04fractionEthane_0041182099doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 03fractionHydrogen_0031182003doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 04fractionPropane_0041182100doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 03fractionOxygen_0031182005doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 04fractionIbutane_0041182106doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 03fractionCarbonMo_0031182004doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 04fractionNbutane_0041182107doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 03fractionWater_0031182001doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 04fractionIpentane_0041182108doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 03fractionH2s_0031182002doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 04fractionNpentane_0041182109doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 03fractionHelium_0031182015doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 04fractionNhexane_0041182110doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 03fractionArgon_0031182016doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 04fractionNheptane_0041182111doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 05fractionMethane_0051182196doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 04fractionNoctane_0041182112doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 05fractionNitrogen_0051182197doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 04fractionNnonane_0041182113doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 05fractionCarbonDi_0051182198doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 04fractionNdecane_0041182114doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 05fractionEthane_0051182199doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 04fractionHydrogen_0041182103doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 05fractionPropane_0051182200doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 04fractionOxygen_0041182105doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 05fractionIbutane_0051182206doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 04fractionCarbonMo_0041182104doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 05fractionNbutane_0051182207doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 04fractionWater_0041182101doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 05fractionIpentane_0051182208doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 04fractionH2s_0041182102doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 05fractionNpentane_0051182209doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 04fractionHelium_0041182115doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 05fractionNhexane_0051182210doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 04fractionArgon_0041182116doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 05fractionNheptane_0051182211doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 06fractionMethane_0061182296doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 05fractionNoctane_0051182212doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 06fractionNitrogen_0061182297doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 05fractionNnonane_0051182213doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 06fractionCarbonDi_0061182298doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 05fractionNdecane_0051182214doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 06fractionEthane_0061182299doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 05fractionHydrogen_0051182203doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 06fractionPropane_0061182300doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 05fractionOxygen_0051182205doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 06fractionIbutane_0061182306doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 05fractionCarbonMo_0051182204doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 06fractionNbutane_0061182307doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 05fractionWater_0051182201doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 06fractionIpentane_0061182308doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 05fractionH2s_0051182202doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 06fractionNpentane_0061182309doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 05fractionHelium_0051182215doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 06fractionNhexane_0061182310doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 05fractionArgon_0051182216doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 06fractionNheptane_0061182311doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 07fractionMethane_0071182396doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 06fractionNoctane_0061182312doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 07fractionNitrogen_0071182397doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 06fractionNnonane_0061182313doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 07fractionCarbonDi_0071182398doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 06fractionNdecane_0061182314doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 07fractionEthane_0071182399doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 06fractionHydrogen_0061182303doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 07fractionPropane_0071182400doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 06fractionOxygen_0061182305doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 07fractionIbutane_0071182406doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 06fractionCarbonMo_0061182304doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 07fractionNbutane_0071182407doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 06fractionWater_0061182301doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 07fractionIpentane_0071182408doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 06fractionH2s_0061182302doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 07fractionNpentane_0071182409doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 06fractionHelium_0061182315doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 07fractionNhexane_0071182410doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 06fractionArgon_0061182316doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 07fractionNheptane_0071182411doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 08fractionMethane_0081182496doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 07fractionNoctane_0071182412doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 08fractionNitrogen_0081182497doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 07fractionNnonane_0071182413doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 08fractionCarbonDi_0081182498doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 07fractionNdecane_0071182414doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 08fractionEthane_0081182499doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 07fractionHydrogen_0071182403doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 08fractionPropane_0081182500doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 07fractionOxygen_0071182405doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 08fractionIbutane_0081182506doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 07fractionCarbonMo_0071182404doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 08fractionNbutane_0081182507doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 07fractionWater_0071182401doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 08fractionIpentane_0081182508doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 07fractionH2s_0071182402doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 08fractionNpentane_0081182509doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 07fractionHelium_0071182415doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 08fractionNhexane_0081182510doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 07fractionArgon_0071182416doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 08fractionNheptane_0081182511doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 09fractionMethane_0091182596doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 08fractionNoctane_0081182512doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 09fractionNitrogen_0091182597doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 08fractionNnonane_0081182513doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 09fractionCarbonDi_0091182598doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 08fractionNdecane_0081182514doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 09fractionEthane_0091182599doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 08fractionHydrogen_0081182503doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 09fractionPropane_0091182600doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 08fractionOxygen_0081182505doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 09fractionIbutane_0091182606doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 08fractionCarbonMo_0081182504doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 09fractionNbutane_0091182607doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 08fractionWater_0081182501doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 09fractionIpentane_0091182608doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 08fractionH2s_0081182502doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 09fractionNpentane_0091182609doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 08fractionHelium_0081182515doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 09fractionNhexane_0091182610doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 08fractionArgon_0081182516doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 09fractionNheptane_0091182611doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 10fractionMethane_0101182696doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 09fractionNoctane_0091182612doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 10fractionNitrogen_0101182697doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 09fractionNnonane_0091182613doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 10fractionCarbonDi_0101182698doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 09fractionNdecane_0091182614doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 10fractionEthane_0101182699doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 09fractionHydrogen_0091182603doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 10fractionPropane_0101182700doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 09fractionOxygen_0091182605doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 10fractionIbutane_0101182706doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 09fractionCarbonMo_0091182604doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 10fractionNbutane_0101182707doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 09fractionWater_0091182601doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 10fractionIpentane_0101182708doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 09fractionH2s_0091182602doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 10fractionNpentane_0101182709doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 09fractionHelium_0091182615doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 10fractionNhexane_0101182710doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 09fractionArgon_0091182616doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 10fractionNheptane_0101182711doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 11fractionMethane_0111182796doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 10fractionNoctane_0101182712doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 11fractionNitrogen_0111182797doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 10fractionNnonane_0101182713doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 11fractionCarbonDi_0111182798doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 10fractionNdecane_0101182714doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 11fractionEthane_0111182799doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 10fractionHydrogen_0101182703doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 11fractionPropane_0111182800doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 10fractionOxygen_0101182705doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 11fractionIbutane_0111182806doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 10fractionCarbonMo_0101182704doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 11fractionNbutane_0111182807doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 10fractionWater_0101182701doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 11fractionIpentane_0111182808doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 10fractionH2s_0101182702doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 11fractionNpentane_0111182809doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 10fractionHelium_0101182715doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 11fractionNhexane_0111182810doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 10fractionArgon_0101182716doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 11fractionNheptane_0111182811doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 12fractionMethane_0121182896doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 11fractionNoctane_0111182812doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 12fractionNitrogen_0121182897doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 11fractionNnonane_0111182813doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 12fractionCarbonDi_0121182898doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 11fractionNdecane_0111182814doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 12fractionEthane_0121182899doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 11fractionHydrogen_0111182803doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 12fractionPropane_0121182900doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 11fractionOxygen_0111182805doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 12fractionIbutane_0121182906doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 11fractionCarbonMo_0111182804doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 12fractionNbutane_0121182907doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 11fractionWater_0111182801doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 12fractionIpentane_0121182908doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 11fractionH2s_0111182802doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 12fractionNpentane_0121182909doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 11fractionHelium_0111182815doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 12fractionNhexane_0121182910doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 11fractionArgon_0111182816doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 12fractionNheptane_0121182911doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 13fractionMethane_0131182996doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 12fractionNoctane_0121182912doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 13fractionNitrogen_0131182997doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 12fractionNnonane_0121182913doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 13fractionCarbonDi_0131182998doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 12fractionNdecane_0121182914doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 13fractionEthane_0131182999doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 12fractionHydrogen_0121182903doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 13fractionPropane_0131183000doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 12fractionOxygen_0121182905doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 13fractionIbutane_0131183006doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 12fractionCarbonMo_0121182904doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 13fractionNbutane_0131183007doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 12fractionWater_0121182901doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 13fractionIpentane_0131183008doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 12fractionH2s_0121182902doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 13fractionNpentane_0131183009doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 12fractionHelium_0121182915doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 13fractionNhexane_0131183010doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 12fractionArgon_0121182916doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 13fractionNheptane_0131183011doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 14fractionMethane_0141183096doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 13fractionNoctane_0131183012doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 14fractionNitrogen_0141183097doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 13fractionNnonane_0131183013doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 14fractionCarbonDi_0141183098doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 13fractionNdecane_0131183014doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 14fractionEthane_0141183099doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 13fractionHydrogen_0131183003doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 14fractionPropane_0141183100doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 13fractionOxygen_0131183005doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 14fractionIbutane_0141183106doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 13fractionCarbonMo_0131183004doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 14fractionNbutane_0141183107doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 13fractionWater_0131183001doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 14fractionIpentane_0141183108doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 13fractionH2s_0131183002doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 14fractionNpentane_0141183109doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 13fractionHelium_0131183015doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 14fractionNhexane_0141183110doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 13fractionArgon_0131183016doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 14fractionNheptane_0141183111doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 15fractionMethane_0151183196doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 14fractionNoctane_0141183112doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 15fractionNitrogen_0151183197doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 14fractionNnonane_0141183113doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 15fractionCarbonDi_0151183198doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 14fractionNdecane_0141183114doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 15fractionEthane_0151183199doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 14fractionHydrogen_0141183103doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 15fractionPropane_0151183200doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 14fractionOxygen_0141183105doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 15fractionIbutane_0151183206doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 14fractionCarbonMo_0141183104doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 15fractionNbutane_0151183207doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 14fractionWater_0141183101doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 15fractionIpentane_0151183208doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 14fractionH2s_0141183102doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 15fractionNpentane_0151183209doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 14fractionHelium_0141183115doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 15fractionNhexane_0151183210doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 14fractionArgon_0141183116doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 15fractionNheptane_0151183211doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 16fractionMethane_0161183296doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 15fractionNoctane_0151183212doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 16fractionNitrogen_0161183297doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 15fractionNnonane_0151183213doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 16fractionCarbonDi_0161183298doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 15fractionNdecane_0151183214doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 16fractionEthane_0161183299doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 15fractionHydrogen_0151183203doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 16fractionPropane_0161183300doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 15fractionOxygen_0151183205doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 16fractionIbutane_0161183306doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 15fractionCarbonMo_0151183204doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 16fractionNbutane_0161183307doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 15fractionWater_0151183201doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 16fractionIpentane_0161183308doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 15fractionH2s_0151183202doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 16fractionNpentane_0161183309doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 15fractionHelium_0151183215doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 16fractionNhexane_0161183310doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 15fractionArgon_0151183216doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 16fractionNheptane_0161183311doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 17fractionMethane_0171183396doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 16fractionNoctane_0161183312doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 17fractionNitrogen_0171183397doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 16fractionNnonane_0161183313doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 17fractionCarbonDi_0171183398doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 16fractionNdecane_0161183314doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 17fractionEthane_0171183399doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 16fractionHydrogen_0161183303doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 17fractionPropane_0171183400doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 16fractionOxygen_0161183305doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 17fractionIbutane_0171183406doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 16fractionCarbonMo_0161183304doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 17fractionNbutane_0171183407doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 16fractionWater_0161183301doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 17fractionIpentane_0171183408doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 16fractionH2s_0161183302doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 17fractionNpentane_0171183409doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 16fractionHelium_0161183315doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 17fractionNhexane_0171183410doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 16fractionArgon_0161183316doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 17fractionNheptane_0171183411doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 18fractionMethane_0181183496doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 17fractionNoctane_0171183412doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 18fractionNitrogen_0181183497doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 17fractionNnonane_0171183413doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 18fractionCarbonDi_0181183498doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 17fractionNdecane_0171183414doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 18fractionEthane_0181183499doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 17fractionHydrogen_0171183403doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 18fractionPropane_0181183500doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 17fractionOxygen_0171183405doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 18fractionIbutane_0181183506doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 17fractionCarbonMo_0171183404doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 18fractionNbutane_0181183507doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 17fractionWater_0171183401doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 18fractionIpentane_0181183508doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 17fractionH2s_0171183402doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 18fractionNpentane_0181183509doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 17fractionHelium_0171183415doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 18fractionNhexane_0181183510doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 17fractionArgon_0171183416doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 18fractionNheptane_0181183511doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 19fractionMethane_0191183596doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 18fractionNoctane_0181183512doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 19fractionNitrogen_0191183597doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 18fractionNnonane_0181183513doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 19fractionCarbonDi_0191183598doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 18fractionNdecane_0181183514doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 19fractionEthane_0191183599doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 18fractionHydrogen_0181183503doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 19fractionPropane_0191183600doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 18fractionOxygen_0181183505doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 19fractionIbutane_0191183606doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 18fractionCarbonMo_0181183504doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 19fractionNbutane_0191183607doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 18fractionWater_0181183501doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 19fractionIpentane_0191183608doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 18fractionH2s_0181183502doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 19fractionNpentane_0191183609doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 18fractionHelium_0181183515doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 19fractionNhexane_0191183610doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 18fractionArgon_0181183516doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 19fractionNheptane_0191183611doubleimin:0.0;max:1.0;The fraction of n-Heptane.
Methane 20fractionMethane_0201183696doublei1min:0.0;max:1.0;The fraction of methane.
n-Octane 19fractionNoctane_0191183612doubleimin:0.0;max:1.0;The fraction of n-Octane.
Nitrogen 20fractionNitrogen_0201183697doubleimin:0.0;max:1.0;The fraction of nitrogen.
n-Nonane 19fractionNnonane_0191183613doubleimin:0.0;max:1.0;The fraction of n-Nonane.
Carbon Dioxide 20fractionCarbonDi_0201183698doubleimin:0.0;max:1.0;The fraction of carbon dioxide.
n-Decane 19fractionNdecane_0191183614doubleimin:0.0;max:1.0;The fraction of n-Decane.
Ethane 20fractionEthane_0201183699doubleimin:0.0;max:1.0;The fraction of ethane.
Hydrogen 19fractionHydrogen_0191183603doubleimin:0.0;max:1.0;The fraction of hydrogen.
Propane 20fractionPropane_0201183700doubleimin:0.0;max:1.0;The fraction of propane.
Oxygen 19fractionOxygen_0191183605doubleimin:0.0;max:1.0;The fraction of oxygen.
i-Butane 20fractionIbutane_0201183706doubleimin:0.0;max:1.0;The fraction of i-Butane.
Carbon Monoxide 19fractionCarbonMo_0191183604doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
n-Butane 20fractionNbutane_0201183707doubleimin:0.0;max:1.0;The fraction of n-Butane.
Water 19fractionWater_0191183601doubleimin:0.0;max:1.0;The fraction of water.
i-Pentane 20fractionIpentane_0201183708doubleimin:0.0;max:1.0;The fraction of i-Pentane.
Hydrogen Sulfide 19fractionH2s_0191183602doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
n-Pentane 20fractionNpentane_0201183709doubleimin:0.0;max:1.0;The fraction of n-Pentane.
Helium 19fractionHelium_0191183615doubleimin:0.0;max:1.0;The fraction of helium.
n-Hexane 20fractionNhexane_0201183710doubleimin:0.0;max:1.0;The fraction of n-Hexane.
Argon 19fractionArgon_0191183616doubleimin:0.0;max:1.0;The fraction of argon.
n-Heptane 20fractionNheptane_0201183711doubleimin:0.0;max:1.0;The fraction of n-Heptane.
n-Octane 20fractionNoctane_0201183712doubleimin:0.0;max:1.0;The fraction of n-Octane.
n-Nonane 20fractionNnonane_0201183713doubleimin:0.0;max:1.0;The fraction of n-Nonane.
n-Decane 20fractionNdecane_0201183714doubleimin:0.0;max:1.0;The fraction of n-Decane.
Hydrogen 20fractionHydrogen_0201183703doubleimin:0.0;max:1.0;The fraction of hydrogen.
Oxygen 20fractionOxygen_0201183705doubleimin:0.0;max:1.0;The fraction of oxygen.
Carbon Monoxide 20fractionCarbonMo_0201183704doubleimin:0.0;max:1.0;The fraction of carbon monoxide.
Water 20fractionWater_0201183701doubleimin:0.0;max:1.0;The fraction of water.
Hydrogen Sulfide 20fractionH2s_0201183702doubleimin:0.0;max:1.0;The fraction of hydrogen sulfide.
Helium 20fractionHelium_0201183715doubleimin:0.0;max:1.0;The fraction of helium.
Argon 20fractionArgon_0201183716doubleimin:0.0;max:1.0;The fraction of argon.

Group 'Liquid Config'

Configure liquid products.

This is a configuration group that has 126 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Density Type 01densityType_0011247332i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 01fixedDensity_0011247333doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 01liqProdType_0011247334i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 01baseDensityOil_0011247335doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 01baseDensityWater_0011247336doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 01corrFactOil_0011247337doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 02densityType_0021247432i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 02fixedDensity_0021247433doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 02liqProdType_0021247434i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 02baseDensityOil_0021247435doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 02baseDensityWater_0021247436doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 02corrFactOil_0021247437doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 03densityType_0031247532i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 03fixedDensity_0031247533doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 03liqProdType_0031247534i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 03baseDensityOil_0031247535doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 03baseDensityWater_0031247536doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 03corrFactOil_0031247537doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 04densityType_0041247632i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 04fixedDensity_0041247633doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 04liqProdType_0041247634i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 04baseDensityOil_0041247635doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 04baseDensityWater_0041247636doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 04corrFactOil_0041247637doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 05densityType_0051247732i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 05fixedDensity_0051247733doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 05liqProdType_0051247734i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 05baseDensityOil_0051247735doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 05baseDensityWater_0051247736doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 05corrFactOil_0051247737doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 06densityType_0061247832i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 06fixedDensity_0061247833doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 06liqProdType_0061247834i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 06baseDensityOil_0061247835doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 06baseDensityWater_0061247836doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 06corrFactOil_0061247837doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 07densityType_0071247932i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 07fixedDensity_0071247933doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 07liqProdType_0071247934i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 07baseDensityOil_0071247935doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 07baseDensityWater_0071247936doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 07corrFactOil_0071247937doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 08densityType_0081248032i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 08fixedDensity_0081248033doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 08liqProdType_0081248034i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 08baseDensityOil_0081248035doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 08baseDensityWater_0081248036doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 08corrFactOil_0081248037doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 09densityType_0091248132i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 09fixedDensity_0091248133doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 09liqProdType_0091248134i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 09baseDensityOil_0091248135doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 09baseDensityWater_0091248136doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 09corrFactOil_0091248137doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 10densityType_0101248232i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 10fixedDensity_0101248233doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 10liqProdType_0101248234i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 10baseDensityOil_0101248235doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 10baseDensityWater_0101248236doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 10corrFactOil_0101248237doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 11densityType_0111248332i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 11fixedDensity_0111248333doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 11liqProdType_0111248334i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 11baseDensityOil_0111248335doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 11baseDensityWater_0111248336doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 11corrFactOil_0111248337doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 12densityType_0121248432i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 12fixedDensity_0121248433doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 12liqProdType_0121248434i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 12baseDensityOil_0121248435doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 12baseDensityWater_0121248436doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 12corrFactOil_0121248437doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 13densityType_0131248532i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 13fixedDensity_0131248533doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 13liqProdType_0131248534i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 13baseDensityOil_0131248535doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 13baseDensityWater_0131248536doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 13corrFactOil_0131248537doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 14densityType_0141248632i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 14fixedDensity_0141248633doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 14liqProdType_0141248634i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 14baseDensityOil_0141248635doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 14baseDensityWater_0141248636doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 14corrFactOil_0141248637doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 15densityType_0151248732i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 15fixedDensity_0151248733doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 15liqProdType_0151248734i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 15baseDensityOil_0151248735doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 15baseDensityWater_0151248736doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 15corrFactOil_0151248737doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 16densityType_0161248832i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 16fixedDensity_0161248833doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 16liqProdType_0161248834i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 16baseDensityOil_0161248835doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 16baseDensityWater_0161248836doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 16corrFactOil_0161248837doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 17densityType_0171248932i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 17fixedDensity_0171248933doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 17liqProdType_0171248934i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 17baseDensityOil_0171248935doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 17baseDensityWater_0171248936doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 17corrFactOil_0171248937doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 18densityType_0181249032i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 18fixedDensity_0181249033doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 18liqProdType_0181249034i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 18baseDensityOil_0181249035doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 18baseDensityWater_0181249036doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 18corrFactOil_0181249037doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 19densityType_0191249132i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 19fixedDensity_0191249133doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 19liqProdType_0191249134i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 19baseDensityOil_0191249135doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 19baseDensityWater_0191249136doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 19corrFactOil_0191249137doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.
Density Type 20densityType_0201249232i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input. Select 'Live' when the density is available in the PLC. Select 'Fixed' to use a fixed value for the density. Select 'Coriolis Meter' to read the density directly from a Coriolis Meter. Direct polling of the meter must be enabled when this option is selected.
Fixed Density 20fixedDensity_0201249233doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density. This is required when the 'Density Input Type' is 'Fixed' and can be ignored otherwise.
Product Type 20liqProdType_0201249234i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of product being measured.
Base Density Oil 20baseDensityOil_0201249235doublei600min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture.
Base Density Water 20baseDensityWater_0201249236doublei1000min:0.1;max:2000.0;1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture.
Correction Factor Oil 20corrFactOil_0201249237doublei1min:0.1;max:10.0;A correction factor for the oil measurement. The calculated value will be multiplied by this value.

Group 'Water Config'

Configure water products.

This is a configuration group that has 21 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Correction Factor Water 01corrFactWater_0011312868doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 02corrFactWater_0021312968doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 03corrFactWater_0031313068doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 04corrFactWater_0041313168doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 05corrFactWater_0051313268doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 06corrFactWater_0061313368doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 07corrFactWater_0071313468doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 08corrFactWater_0081313568doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 09corrFactWater_0091313668doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 10corrFactWater_0101313768doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 11corrFactWater_0111313868doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 12corrFactWater_0121313968doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 13corrFactWater_0131314068doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 14corrFactWater_0141314168doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 15corrFactWater_0151314268doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 16corrFactWater_0161314368doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 17corrFactWater_0171314468doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 18corrFactWater_0181314568doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 19corrFactWater_0191314668doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.
Correction Factor Water 20corrFactWater_0201314768doublei1min:0.1;max:10.0;A correction factor for the water measurement. The calculated value will be multiplied by this value.

Group 'Well Tests'

Configure well tests.

This is a configuration group that has 294 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Enable Test 01testEn_0011378404booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Description 01testDesc_0011378405stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 01testMetadata_0011378406stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Test Asset ID 01testAssetId_0011378407i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Site Specific Delay 01siteSpecificDelay_0011378408i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Test Enable Gas 01testEnGas_0011378409booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Test Enable Liquid 01testEnLiquid_0011378411booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 01testEnWater_0011378413booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 02testEn_0021378504booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 01testDuration_0011378415i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 02testDesc_0021378505stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 02testMetadata_0021378506stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 01purgeTimeMin_0011378420i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 02testAssetId_0021378507i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 01purgeTimeMax_0011378421i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 02siteSpecificDelay_0021378508i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 01purgeVolGas_0011378417doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 02testEnGas_0021378509booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 01purgeVolLiquid_0011378418doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 01purgeVolWater_0011378419doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 02testEnLiquid_0021378511booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 02testEnWater_0021378513booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 03testEn_0031378604booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 02testDuration_0021378515i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 03testDesc_0031378605stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 03testMetadata_0031378606stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 02purgeTimeMin_0021378520i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 03testAssetId_0031378607i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 02purgeTimeMax_0021378521i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 03siteSpecificDelay_0031378608i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 02purgeVolGas_0021378517doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 03testEnGas_0031378609booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 02purgeVolLiquid_0021378518doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 02purgeVolWater_0021378519doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 03testEnLiquid_0031378611booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 03testEnWater_0031378613booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 04testEn_0041378704booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 03testDuration_0031378615i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 04testDesc_0041378705stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 04testMetadata_0041378706stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 03purgeTimeMin_0031378620i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 04testAssetId_0041378707i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 03purgeTimeMax_0031378621i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 04siteSpecificDelay_0041378708i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 03purgeVolGas_0031378617doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 04testEnGas_0041378709booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 03purgeVolLiquid_0031378618doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 03purgeVolWater_0031378619doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 04testEnLiquid_0041378711booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 04testEnWater_0041378713booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 05testEn_0051378804booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 04testDuration_0041378715i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 05testDesc_0051378805stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 05testMetadata_0051378806stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 04purgeTimeMin_0041378720i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 05testAssetId_0051378807i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 04purgeTimeMax_0041378721i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 05siteSpecificDelay_0051378808i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 04purgeVolGas_0041378717doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 05testEnGas_0051378809booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 04purgeVolLiquid_0041378718doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 04purgeVolWater_0041378719doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 05testEnLiquid_0051378811booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 05testEnWater_0051378813booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 06testEn_0061378904booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 05testDuration_0051378815i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 06testDesc_0061378905stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 06testMetadata_0061378906stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 05purgeTimeMin_0051378820i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 06testAssetId_0061378907i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 05purgeTimeMax_0051378821i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 06siteSpecificDelay_0061378908i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 05purgeVolGas_0051378817doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 06testEnGas_0061378909booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 05purgeVolLiquid_0051378818doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 05purgeVolWater_0051378819doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 06testEnLiquid_0061378911booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 06testEnWater_0061378913booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 07testEn_0071379004booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 06testDuration_0061378915i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 07testDesc_0071379005stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 07testMetadata_0071379006stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 06purgeTimeMin_0061378920i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 07testAssetId_0071379007i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 06purgeTimeMax_0061378921i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 07siteSpecificDelay_0071379008i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 06purgeVolGas_0061378917doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 07testEnGas_0071379009booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 06purgeVolLiquid_0061378918doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 06purgeVolWater_0061378919doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 07testEnLiquid_0071379011booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 07testEnWater_0071379013booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 08testEn_0081379104booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 07testDuration_0071379015i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 08testDesc_0081379105stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 08testMetadata_0081379106stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 07purgeTimeMin_0071379020i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 08testAssetId_0081379107i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 07purgeTimeMax_0071379021i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 08siteSpecificDelay_0081379108i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 07purgeVolGas_0071379017doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 08testEnGas_0081379109booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 07purgeVolLiquid_0071379018doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 07purgeVolWater_0071379019doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 08testEnLiquid_0081379111booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 08testEnWater_0081379113booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 09testEn_0091379204booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 08testDuration_0081379115i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 09testDesc_0091379205stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 09testMetadata_0091379206stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 08purgeTimeMin_0081379120i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 09testAssetId_0091379207i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 08purgeTimeMax_0081379121i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 09siteSpecificDelay_0091379208i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 08purgeVolGas_0081379117doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 09testEnGas_0091379209booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 08purgeVolLiquid_0081379118doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 08purgeVolWater_0081379119doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 09testEnLiquid_0091379211booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 09testEnWater_0091379213booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 10testEn_0101379304booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 09testDuration_0091379215i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 10testDesc_0101379305stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 10testMetadata_0101379306stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 09purgeTimeMin_0091379220i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 10testAssetId_0101379307i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 09purgeTimeMax_0091379221i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 10siteSpecificDelay_0101379308i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 09purgeVolGas_0091379217doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 10testEnGas_0101379309booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 09purgeVolLiquid_0091379218doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 09purgeVolWater_0091379219doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 10testEnLiquid_0101379311booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 10testEnWater_0101379313booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 11testEn_0111379404booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 10testDuration_0101379315i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 11testDesc_0111379405stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 11testMetadata_0111379406stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 10purgeTimeMin_0101379320i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 11testAssetId_0111379407i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 10purgeTimeMax_0101379321i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 11siteSpecificDelay_0111379408i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 10purgeVolGas_0101379317doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 11testEnGas_0111379409booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 10purgeVolLiquid_0101379318doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 10purgeVolWater_0101379319doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 11testEnLiquid_0111379411booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 11testEnWater_0111379413booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 12testEn_0121379504booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 11testDuration_0111379415i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 12testDesc_0121379505stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 12testMetadata_0121379506stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 11purgeTimeMin_0111379420i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 12testAssetId_0121379507i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 11purgeTimeMax_0111379421i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 12siteSpecificDelay_0121379508i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 11purgeVolGas_0111379417doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 12testEnGas_0121379509booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 11purgeVolLiquid_0111379418doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 11purgeVolWater_0111379419doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 12testEnLiquid_0121379511booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 12testEnWater_0121379513booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 13testEn_0131379604booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 12testDuration_0121379515i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 13testDesc_0131379605stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 13testMetadata_0131379606stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 12purgeTimeMin_0121379520i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 13testAssetId_0131379607i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 12purgeTimeMax_0121379521i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 13siteSpecificDelay_0131379608i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 12purgeVolGas_0121379517doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 13testEnGas_0131379609booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 12purgeVolLiquid_0121379518doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 12purgeVolWater_0121379519doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 13testEnLiquid_0131379611booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 13testEnWater_0131379613booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 14testEn_0141379704booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 13testDuration_0131379615i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 14testDesc_0141379705stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 14testMetadata_0141379706stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 13purgeTimeMin_0131379620i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 14testAssetId_0141379707i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 13purgeTimeMax_0131379621i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 14siteSpecificDelay_0141379708i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 13purgeVolGas_0131379617doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 14testEnGas_0141379709booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 13purgeVolLiquid_0131379618doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 13purgeVolWater_0131379619doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 14testEnLiquid_0141379711booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 14testEnWater_0141379713booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 15testEn_0151379804booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 14testDuration_0141379715i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 15testDesc_0151379805stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 15testMetadata_0151379806stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 14purgeTimeMin_0141379720i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 15testAssetId_0151379807i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 14purgeTimeMax_0141379721i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 15siteSpecificDelay_0151379808i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 14purgeVolGas_0141379717doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 15testEnGas_0151379809booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 14purgeVolLiquid_0141379718doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 14purgeVolWater_0141379719doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 15testEnLiquid_0151379811booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 15testEnWater_0151379813booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 16testEn_0161379904booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 15testDuration_0151379815i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 16testDesc_0161379905stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 16testMetadata_0161379906stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 15purgeTimeMin_0151379820i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 16testAssetId_0161379907i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 15purgeTimeMax_0151379821i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 16siteSpecificDelay_0161379908i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 15purgeVolGas_0151379817doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 16testEnGas_0161379909booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 15purgeVolLiquid_0151379818doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 15purgeVolWater_0151379819doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 16testEnLiquid_0161379911booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 16testEnWater_0161379913booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 17testEn_0171380004booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 16testDuration_0161379915i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 17testDesc_0171380005stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 17testMetadata_0171380006stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 16purgeTimeMin_0161379920i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 17testAssetId_0171380007i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 16purgeTimeMax_0161379921i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 17siteSpecificDelay_0171380008i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 16purgeVolGas_0161379917doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 17testEnGas_0171380009booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 16purgeVolLiquid_0161379918doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 16purgeVolWater_0161379919doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 17testEnLiquid_0171380011booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 17testEnWater_0171380013booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 18testEn_0181380104booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 17testDuration_0171380015i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 18testDesc_0181380105stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 18testMetadata_0181380106stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 17purgeTimeMin_0171380020i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 18testAssetId_0181380107i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 17purgeTimeMax_0171380021i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 18siteSpecificDelay_0181380108i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 17purgeVolGas_0171380017doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 18testEnGas_0181380109booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 17purgeVolLiquid_0171380018doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 17purgeVolWater_0171380019doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 18testEnLiquid_0181380111booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 18testEnWater_0181380113booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 19testEn_0191380204booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 18testDuration_0181380115i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 19testDesc_0191380205stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 19testMetadata_0191380206stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 18purgeTimeMin_0181380120i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 19testAssetId_0191380207i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 18purgeTimeMax_0181380121i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 19siteSpecificDelay_0191380208i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 18purgeVolGas_0181380117doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 19testEnGas_0191380209booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 18purgeVolLiquid_0181380118doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 18purgeVolWater_0181380119doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 19testEnLiquid_0191380211booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 19testEnWater_0191380213booliTruemin:False;max:True;Whether to enable water measurement for this test.
Enable Test 20testEn_0201380304booliTruemin:False;max:True;Whether this test is enabled. When the operation mode is 'Manual', if the selected test is not enabled, it cannot be started. When the operation mode is 'Auto', this test will be excluded from the automatic sequence when it's not enabled.
Test Duration 19testDuration_0191380215i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Test Description 20testDesc_0201380305stringiminChars:0;maxChars:64; spaces:True; lettersNumbersOnly:False;A description for this specific test. This value will be included in the output records when this test is run.
Test Metadata 20testMetadata_0201380306stringiminChars:0;maxChars:128; spaces:True; lettersNumbersOnly:False;Optional metadata for this test. Enter metadata as key:value pairs separated by semicolons. For example, 'units:°C;size:large;'. Metadata will be included in the output records for this test.
Purge Time Minimum 19purgeTimeMin_0191380220i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Test Asset ID 20testAssetId_0201380307i32i0min:0;max:2147483647;A unique numeric identifier for this well test configuration. This value will be moved to the 'Asset ID' parameter on the flow computers and will also appear in the output records for this well test. This allows record data from the flow computers and from this well test application to be easily linked together for a specific well.
Purge Time Maximum 19purgeTimeMax_0191380221i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Site Specific Delay 20siteSpecificDelay_0201380308i16i10min:0;max:3600;640:seconds;640:seconds; The amount of time to wait in the 'Site Specific Delay' state when a well test is started. This delay allows the PLC to move valves or do other tasks after a well test is started.
Purge Volume Gas 19purgeVolGas_0191380217doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Test Enable Gas 20testEnGas_0201380309booliTruemin:False;max:True;Whether to enable gas measurement for this test.
Purge Volume Liquid 19purgeVolLiquid_0191380218doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 19purgeVolWater_0191380219doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.
Test Enable Liquid 20testEnLiquid_0201380311booliTruemin:False;max:True;Whether to enable liquid measurement for this test.
Test Enable Water 20testEnWater_0201380313booliTruemin:False;max:True;Whether to enable water measurement for this test.
Test Duration 20testDuration_0201380315i16i10min:1;max:6000;642:minutes;642:minutes; The length of the test.
Purge Time Minimum 20purgeTimeMin_0201380320i32i10min:0;max:6000;640:seconds;640:seconds; 642:minutes; The minimum amount of time to spend in the 'Purge' state. If purge volumes are reached before this time has elapsed, the application will remain in the 'Purge' state until this time has expired. This value must be less than 'Purge Time Maximum'.
Purge Time Maximum 20purgeTimeMax_0201380321i32i60min:0;max:6000;640:seconds;640:seconds; 642:minutes; The maximum amount of time to spend in the 'Purge' state. The purge volumes are not reached by this time when in the 'Purge' state, the app will move to the next state. This value must be greater than 'Purge Time Minimum'.
Purge Volume Gas 20purgeVolGas_0201380317doubleimin:0.0;max:1000000.0;1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The well test application will stay in the 'Purge' state until this volume of gas has flowed through the system.
Purge Volume Liquid 20purgeVolLiquid_0201380318doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of liquid has flowed through the system.
Purge Volume Water 20purgeVolWater_0201380319doubleimin:0.0;max:1000000.0;1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The well test application will stay in the 'Purge' state until this volume of water has flowed through the system.

Group 'Database Config'

Manage how much flow computer data is saved to disk by the app

This is a configuration group that has 1 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Max HistorydbMaxHistory1441792i16i7min:1;max:365;The number of calendar days to keep well test history data in the local database. Data older than this number of days will be deleted periodically. This value normally doesn't need to be changed, but it can lowered so that the well test app uses less disk space, or can be increased if data is only retrieved occasionally.

Group 'Operation'

Configure the operation mode.

This is a configuration group that has 4 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Operation ModeopMode1507328i32i0:Manual0:Manual; 1:Auto; Choose 'Manual' to select the well on test and start and stop tests through operator intervention. When a test is complete the system will wait until another test is started manually. Choose 'Auto' to have the system cycle through enabled well tests automatically. When a test is complete, the next enabled test will be started automatically.
Auto Test Delay StartautoTestDelayStart1507329booliFalsemin:False;max:True;Select this option when you want automated tests to start at the hour specified in the 'Auto Test Start Hour' parameter. Do not select this option if you want an a test to start immediately after the previous test is complete without any delay.
Auto Test Start HourautoTestStartHour1507330i16i0min:0;max:23;The hour of the day in local time at which automatic tests will be started. When in auto mode, when a test is complete, the next test will be started at this time.
Automatic SequenceautoSequence1507331stringi1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;minChars:2;maxChars:128; spaces:False; lettersNumbersOnly:False;The sequence in which to run automated well tests. When a test is complete, the program will start the next test in the sequence. The sequence will be restarted when it is complete. The sequence must be entered as well test numbers separated by semicolons. The numbers must be between 1 and 20 inclusive and there must be a final trailing semicolon.

Group 'Control'

Control the application

This is a control group that has 5 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Well On Test InputwellOnTestIn8388608i16io1min:1;max:20;Select the well test configuration to use when the operation mode is 'Manual'. This parameter has no effect when the operation mode is 'Auto'.
Start TeststartTestManual8388609boolioFalsemin:False;max:True;Start or stop a well test when the operation mode is 'Manual'. This parameter has no effect when the operation mode is 'Auto'.
Auto End TestautoEndCurrentTest8388612boolioFalsemin:False;max:True;When the operation mode is 'Auto', set this value to immediately end the current test and move to the next test in the sequence. If the current test has entered the 'Test' mode then a record will be written, otherwise no record will be written.
Auto Restart SequenceautoRestartSeq8388613boolioFalsemin:False;max:True;When the operation mode is 'Auto', set this value to immediately end the current test and move to the first test in the sequence. If the current test has entered the 'Test' mode then a record will be written, otherwise no record will be written.
End PurgeendPurge8388614boolioFalsemin:False;max:True;When in the 'Purge' state, set to true to end purge and move to the next state immediately. This has no effect when not in the 'Purge' state.

Group 'Configuration Group Status'

Parameters in this group indicate the status of the associated configuration group.

This is a status group that has 7 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Flow Runs Group Configuration InvalidflRnsGrpInVld5242880booloIndicates whether the pending configuration of the Flow Runs group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Database Config Group Configuration InvaliddbConfigGrpInVld5242881booloIndicates whether the pending configuration of the Database group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Gas Flow Config Group Configuration InvalidgfCfgGrpInVld5242882booloIndicates whether the pending configuration of the Gas Flow Config group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Liquid Flow Config Group Configuration InvalidlfCfgGrpInVld5242883booloIndicates whether the pending configuration of the Liquid Flow Config group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Water Flow Config Group Configuration InvalidwfCfgGrpInVld5242884booloIndicates whether the pending configuration of the Water Flow Config group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Well Test Config Group Configuration InvalidwtCfgGrpInVld5242885booloIndicates whether the pending configuration of the Well Test group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.
Operations Group Configuration InvalidopCfgGrpInVld5242886booloIndicates whether the pending configuration of the Operations group is valid or invalid. A low value indicates a valid configuration. A high value indicates an invalid configuration.

Group 'Database Status'

Status information about the flow history database for this app

This is a status group that has 2 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Database SizedbSizeOnDisk5308416ui32oThe size of the well test history database on disk in bytes.
History Record CountdbHisCount5308417i32oThe number of well test history records stored in the local database. This value is updated about once a minute.

Group 'Selected Test Config'

Shows the configuration for the selected well or the well on test.

This is a status group that has 41 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Selected Test NumbertstNum5373952i16oThe currently selected well test configuration. When the operation mode is 'Manual', select a well test using the 'Well On Test Input' control parameter. When the operation mode is 'Auto', this is the currently active test.
Selected Test DescriptiontstDesc5373953stringoThe configured description for the selected well test.
Selected Test MetadatatstMetadata5373996stringoThe configured metadata for the selected well test.
Selected Test Asset IDtstAssetId5373954i32oThe configured asset ID for the selected well test.
Selected Test DurationtstDuration5373955i16o642:minutes;642:minutes; The configured duration for the selected well test.
Selected Test Purge Min TimetstPrgTimeMin5373994i32o640:seconds;640:seconds; 642:minutes; The configured purge minimum time for the selcted well on test.
Selected Test Purge Max TimetstPrgTimeMax5373995i32o640:seconds;640:seconds; 642:minutes; The configured purge maximum time for the selcted well on test.
Selected Test Gas EnabletstEnGas5373957booloWhether gas measurement is enabled for the selected well test.
Selected Test Gas Purge VolumetstPrgVolGas5373959doubleo1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The configured gas purge volume for the selected well test.
Selected Test MethanetstMethane5373960doubleiThe fraction of methane for the selected well test.
Selected Test NitrogentstNitrogen5373961doubleiThe fraction of nitrogen for the selected well test.
Selected Test Carbon DioxidetstCarbonDi5373962doubleiThe fraction of carbon dioxide for the selected well test.
Selected Test EthanetstEthane5373963doubleiThe fraction of ethane for the selected well test.
Selected Test PropanetstPropane5373964doubleiThe fraction of propane for the selected well test.
Selected Test WatertstWater5373965doubleiThe fraction of water for the selected well test.
Selected Test Hydrogen SulfidetstH2s5373966doubleiThe fraction of hydrogen sulfide for the selected well test.
Selected Test HydrogentstHydrogen5373967doubleiThe fraction of hydrogen for the selected well test.
Selected Test Carbon MonoxidetstCarbonMo5373968doubleiThe fraction of carbon monoxide for the selected well test.
Selected Test OxygentstOxygen5373969doubleiThe fraction of oxygen for the selected well test.
Selected Test i-ButanetstIbutane5373970doubleiThe fraction of i-Butane for the selected well test.
Selected Test n-ButanetstNbutane5373971doubleiThe fraction of n-Butane for the selected well test.
Selected Test i-PentanetstIpentane5373972doubleiThe fraction of i-Pentane for the selected well test.
Selected Test n-PentanetstNpentane5373973doubleiThe fraction of n-Pentane for the selected well test.
Selected Test n-HexanetstNhexane5373974doubleiThe fraction of n-Hexane for the selected well test.
Selected Test n-HeptanetstNheptane5373975doubleiThe fraction of n-Heptane for the selected well test.
Selected Test n-OctanetstNoctane5373976doubleiThe fraction of n-Octane for the selected well test.
Selected Test n-NonanetstNnonane5373977doubleiThe fraction of n-Nonane for the selected well test.
Selected Test n-DecanetstNdecane5373978doubleiThe fraction of n-Decane for the selected well test.
Selected Test HeliumtstHelium5373979doubleiThe fraction of helium for the selected well test.
Selected Test ArgontstArgon5373980doubleiThe fraction of argon for the selected well test.
Selected Test Liquid EnabletstEnLiq5373981booloWhether liquid measurement is enabled for the selected well test.
Selected Test Liquid Purge VolumetstPrgVolLiq5373983doubleo1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The configured liquid purge volume for the selected well test.
Selected Test Density TypetstdensType5373984i32i0:Live0:Live; 1:Fixed; 2:Coriolis Meter; The type of input to use for the density input for the selected well test.
Selected Test Fixed DensitytstfixedDens5373985doublei1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The value of the fixed density for the selected well test.
Selected Test Product TypetstLiqProdType5373986i32i0:Crude Oil0:Crude Oil; 1:Fuel Oil; 2:Jet Fuel; 3:Transition Zone; 4:Gasoline; 5:Lubrication Oil; 6:Natural Gas Products; The specific type of liquid product being measured for the selected well test.
Selected Test Base Density OiltstBaseDensOil5373987doublei1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of oil in the mixture for the selected well test.
Selected Test Base Density WatertstBaseDensWater5373988doublei1920:kg_m3;1920:kg_m3; 1921:lbm_ft3; 1922:degreesApi; The base density of water in the mixture for the selected well test.
Selected Test Correction Factor OiltstCorrFactOil5373989doubleiA correction factor for the oil measurement for the selected well test.
Selected Test Water EnabletstEnWtr5373990booloWhether water measurement is enabled for the selected well test.
Selected Test Water Purge VolumetstPrgVolWtr5373992doubleo1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The configured water purge volume for the selected well test.
Selected Test Correction Factor WatertstCorrFactWtr5373993doubleiA correction factor for the water measurement for the selected well test.

Group 'Flow Run Status'

Information about the flow computer apps.

This is a status group that has 18 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Gas Flow Run ConnectedflStatGasConn5439488booloWhether the well test application is connected to the gas flow application. It's a critical error if the well test application cannot communicate with the gas flow application, assuming that gas flow is enabled.
Gas Flow Run Inputs InvalidflStatGasInInvalid5439500booloThe input values to the flow computer are not valid.
Gas Flow Run Zero FlowflStatGasZeroFlow5439501booloSet when there is zero flow.
Gas Calculation ValidflStatGasCalcValid5439489booloWhether the gas flow calculation from the gas flow computer is valid.
Gas Flow Alarm ActiveflStatGasAlrm5439490booloWhether the gas flow computer has an active alarm. Check the gas flow app for specifics on the active alarm.
Gas Flow Corrected Flow RateflStatGasFlowRt5439491doubleo512:e3m3_day;512:e3m3_day; 513:m3_hr; 514:m3_s; 515:ft3_hr; 516:mmcf_day; 517:mcf_hr; 518:mcf_day; 519:mmcf_hr; The corrected flow rate from the gas flow computer.
Liquid Flow Run ConnectedflStatLiqConn5439492booloWhether the well test application is connected to the liquid flow application. It's a critical error if the well test application cannot communicate with the liquid flow application, assuming that liquid flow is enabled.
Liquid Flow Run Inputs InvalidflStatLiqInInvalid5439502booloThe input values to the flow computer are not valid.
Liquid Flow Run Zero FlowflStatLiqZeroFlow5439503booloSet when there is zero flow.
Liquid Calculation ValidflStatLiqValid5439493booloWhether the liquid flow calculation from the liquid flow computer is valid.
Liquid Flow Alarm ActiveflStatLiqAlrm5439494booloWhether the liquid flow computer has an active alarm. Check the liquid flow app for specifics on the active alarm.
Liquid Flow Corrected Flow RateflStatLiqFlowRt5439495doubleo1664:lqf_m3_day;1664:lqf_m3_day; 1665:lqf_m3_hr; 1666:lqf_e3m3_day; 1667:lqf_m3_s; 1668:lqf_ft3_hr; 1669:lqf_bbl_hr; 1670:lqf_gal_hr; 1671:lqf_bbl_day; 1672:lqf_gal_day; The corrected flow rate from the liquid flow computer.
Water Flow Run ConnectedflStatWtrConn5439496booloWhether the well test application is connected to the water flow application. It's a critical error if the well test application cannot communicate with the water flow application, assuming that water flow is enabled.
WaterFlow Run Inputs InvalidflStatWtrInInvalid5439504booloThe input values to the flow computer are not valid.
Water Flow Run Zero FlowflStatWtrZeroFlow5439505booloSet when there is zero flow.
Water Calculation ValidflStatWtrValid5439497booloWhether the water flow calculation from the liquid flow computer is valid.
Liquid Flow Alarm ActiveflStatWtrAlrm5439498booloWhether the water flow computer has an active alarm. Check the water flow app for specifics on the active alarm.
Water Flow Corrected Flow RateflStatWtrFlowRt5439499doubleo1664:lqf_m3_day;1664:lqf_m3_day; 1665:lqf_m3_hr; 1666:lqf_e3m3_day; 1667:lqf_m3_s; 1668:lqf_ft3_hr; 1669:lqf_bbl_hr; 1670:lqf_gal_hr; 1671:lqf_bbl_day; 1672:lqf_gal_day; The corrected flow rate from the water flow computer.

Group 'Current Test'

Information about the test that is currently underway.

This is a status group that has 24 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
Test StatecurTestState5505024i32i0:Waiting0:Waiting; 1:Site Specific; 2:Configure; 3:Confirm Configure; 4:Start Purge; 5:Purge; 6:Start Batch; 7:Test; 8:Stop Test; 9:Done; The control state of the well test in progress.
Time In StatecurTimeInState5505025i32i640:seconds;640:seconds; The time in the current control state for the well test in progress. This value is reset to 0 on every control state change.
Well On Test NumbercurWellCfgOnTest5505026i16iThe numeric identifier of the currently active well test configuration.
Auto Test Sequence IndexcurAutoSequenceIdx5505045i16iWhen the operation mode is 'Auto', this indicates the program's location in the automatic sequence. For example, if the sequence is configured to test six wells, and the program is testing the second well in the sequence, this value would be two.
Auto Test Next WellcurNextTestAuto5505046i16iWhen the operation mode is 'Auto', this value shows the next well number that will be tested.
Test IDcurTestId5505027i32iThe unique ID of the active well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
Asset IDcurAssetId5505047i32iThe configured Asset ID of the active well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
Purge Start TimestampcurPurgeStartTs5505028ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for the current well test.
Purge Elapsed TimecurPurgeTimeElapsed5505029doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for the current well test. This value is reset to 0 when a new test is started.
Current Test Purge Volume GascurPurgeVolGas5505030doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state.
Current Test Purge Volume LiquidcurPurgeVolLiq5505031doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state.
Current Test Purge Volume WatercurPurgeVolWtr5505032doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state.
Test Start Time UTCcurTestStartTs5505033ui32i4:unixSeconds;4:unixSeconds; The time at which the current well test was started.
Test Scheduled End Time UTCcurTestSchEndTs5505034ui32i4:unixSeconds;4:unixSeconds; The time at which the current well test is scheduled to end.
Test Elapsed TimecurTestTimeElapsed5505035doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time that has elapsed since this well test was started. This does not include time in the 'Purge' state. It only includes time where the well is on test.
Test Remaining TimecurTestTimeRemaining5505036doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time remaining until the active well test is complete.
Test Event CountcurTestEventCount5505037i16iThe number of events that have occurred for all flow computers during this test. This includes events after configuration is complete and also includes events that occur when in the 'Purge' state. This number should normally be 0 because configuration changes and other events should not normally occur during testing.
Test Alarm CountcurTesAlarmCount5505038i16iThe number of alarms that have occurred for all flow computers during this test. This includes alarms from the time that the well test is started, and as such, includes alarms generated when in the 'Purge' state. This number should normally be 0 because alarms should not occur while well testing is underway.
Test Volume GascurTestVolGas5505039doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for the active well test.
Test Volume LiquidcurTestVolLiq5505040doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the active well test.
Test Volume WatercurTestVolWtr5505041doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for the active well test.
Prorated Volume GascurTestProVolGas5505042doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for the active well test prorated to a 24 hour test. For example, if the actual volume is 0.5 e3m3 and the test has been underway for 1 hour, the prorated volume would be 0.5 * 24 = 12 e3m3.
Prorated Volume LiquidcurTestProVolLiq5505043doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the active well test prorated to a 24 hour test. For example, if the actual volume is 0.5 m3 and the test has been underway for 1 hour, the prorated volume would be 0.5 * 24 = 12 m3.
Prorated Volume WatercurTestProVolWtr5505044doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for the active well test prorated to a 24 hour test. For example, if the actual volume is 0.5 m3 and the test has been underway for 1 hour, the prorated volume would be 0.5 * 24 = 12 m3.

Group 'Test History'

Information about completed tests.

This is a status group that has 209 parameters.

ParameterTag NameIDValue TypeTag Value TypeIO TypeDefault ValueLimitsDefault UnitsAllowed UnitsDescriptionSync EnabledSync DefaultExport EnabledPublish MQTT EnabledSubscribe MQTT EnabledShow in Manager EnabledModbus Server EnabledgRPC Read EnabledgRPC Write Enabled
History Well On Test Number 01hisWellCfgOnTest_0015572708i16iThe numeric identifier of the well test configuration for this well test.
History Test ID 01hisTestId_0015572709i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 01hisAssetId_0015572726i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Purge Start Time UTC 01hisPurgeStartTs_0015572710ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Purge Elapsed Time 01hisPurgeTimeElapsed_0015572711doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Purge Volume Gas 01hisPurgeVolGas_0015572712doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Purge Volume Liquid 01hisPurgeVolLiq_0015572713doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Purge Volume Water 01hisPurgeVolWtr_0015572714doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Start Time UTC 01hisTestStartTs_0015572715ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 01hisTestEndTs_0015572716ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 01hisTestTimeElapsed_0015572717doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 01hisTestEventCount_0015572718i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 02hisWellCfgOnTest_0025572808i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 01hisTesAlarmCount_0015572719i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 02hisTestId_0025572809i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 02hisAssetId_0025572826i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 01hisTestVolGas_0015572720doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 02hisPurgeStartTs_0025572810ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 01hisTestVolLiq_0015572721doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 02hisPurgeTimeElapsed_0025572811doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 01hisTestVolWtr_0015572722doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 02hisPurgeVolGas_0025572812doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 01hisTestProVolGas_0015572723doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 02hisPurgeVolLiq_0025572813doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 01hisTestProVolLiq_0015572724doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 02hisPurgeVolWtr_0025572814doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 01hisTestProVolWtr_0015572725doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 02hisTestStartTs_0025572815ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 02hisTestEndTs_0025572816ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 02hisTestTimeElapsed_0025572817doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 02hisTestEventCount_0025572818i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 03hisWellCfgOnTest_0035572908i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 02hisTesAlarmCount_0025572819i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 03hisTestId_0035572909i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 03hisAssetId_0035572926i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 02hisTestVolGas_0025572820doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 03hisPurgeStartTs_0035572910ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 02hisTestVolLiq_0025572821doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 03hisPurgeTimeElapsed_0035572911doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 02hisTestVolWtr_0025572822doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 03hisPurgeVolGas_0035572912doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 02hisTestProVolGas_0025572823doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 03hisPurgeVolLiq_0035572913doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 02hisTestProVolLiq_0025572824doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 03hisPurgeVolWtr_0035572914doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 02hisTestProVolWtr_0025572825doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 03hisTestStartTs_0035572915ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 03hisTestEndTs_0035572916ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 03hisTestTimeElapsed_0035572917doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 03hisTestEventCount_0035572918i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 04hisWellCfgOnTest_0045573008i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 03hisTesAlarmCount_0035572919i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 04hisTestId_0045573009i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 04hisAssetId_0045573026i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 03hisTestVolGas_0035572920doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 04hisPurgeStartTs_0045573010ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 03hisTestVolLiq_0035572921doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 04hisPurgeTimeElapsed_0045573011doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 03hisTestVolWtr_0035572922doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 04hisPurgeVolGas_0045573012doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 03hisTestProVolGas_0035572923doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 04hisPurgeVolLiq_0045573013doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 03hisTestProVolLiq_0035572924doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 04hisPurgeVolWtr_0045573014doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 03hisTestProVolWtr_0035572925doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 04hisTestStartTs_0045573015ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 04hisTestEndTs_0045573016ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 04hisTestTimeElapsed_0045573017doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 04hisTestEventCount_0045573018i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 05hisWellCfgOnTest_0055573108i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 04hisTesAlarmCount_0045573019i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 05hisTestId_0055573109i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 05hisAssetId_0055573126i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 04hisTestVolGas_0045573020doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 05hisPurgeStartTs_0055573110ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 04hisTestVolLiq_0045573021doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 05hisPurgeTimeElapsed_0055573111doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 04hisTestVolWtr_0045573022doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 05hisPurgeVolGas_0055573112doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 04hisTestProVolGas_0045573023doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 05hisPurgeVolLiq_0055573113doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 04hisTestProVolLiq_0045573024doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 05hisPurgeVolWtr_0055573114doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 04hisTestProVolWtr_0045573025doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 05hisTestStartTs_0055573115ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 05hisTestEndTs_0055573116ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 05hisTestTimeElapsed_0055573117doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 05hisTestEventCount_0055573118i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 06hisWellCfgOnTest_0065573208i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 05hisTesAlarmCount_0055573119i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 06hisTestId_0065573209i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 06hisAssetId_0065573226i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 05hisTestVolGas_0055573120doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 06hisPurgeStartTs_0065573210ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 05hisTestVolLiq_0055573121doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 06hisPurgeTimeElapsed_0065573211doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 05hisTestVolWtr_0055573122doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 06hisPurgeVolGas_0065573212doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 05hisTestProVolGas_0055573123doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 06hisPurgeVolLiq_0065573213doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 05hisTestProVolLiq_0055573124doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 06hisPurgeVolWtr_0065573214doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 05hisTestProVolWtr_0055573125doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 06hisTestStartTs_0065573215ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 06hisTestEndTs_0065573216ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 06hisTestTimeElapsed_0065573217doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 06hisTestEventCount_0065573218i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 07hisWellCfgOnTest_0075573308i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 06hisTesAlarmCount_0065573219i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 07hisTestId_0075573309i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 07hisAssetId_0075573326i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 06hisTestVolGas_0065573220doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 07hisPurgeStartTs_0075573310ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 06hisTestVolLiq_0065573221doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 07hisPurgeTimeElapsed_0075573311doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 06hisTestVolWtr_0065573222doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 07hisPurgeVolGas_0075573312doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 06hisTestProVolGas_0065573223doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 07hisPurgeVolLiq_0075573313doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 06hisTestProVolLiq_0065573224doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 07hisPurgeVolWtr_0075573314doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 06hisTestProVolWtr_0065573225doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 07hisTestStartTs_0075573315ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 07hisTestEndTs_0075573316ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 07hisTestTimeElapsed_0075573317doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 07hisTestEventCount_0075573318i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 08hisWellCfgOnTest_0085573408i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 07hisTesAlarmCount_0075573319i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 08hisTestId_0085573409i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 08hisAssetId_0085573426i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 07hisTestVolGas_0075573320doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 08hisPurgeStartTs_0085573410ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 07hisTestVolLiq_0075573321doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 08hisPurgeTimeElapsed_0085573411doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 07hisTestVolWtr_0075573322doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 08hisPurgeVolGas_0085573412doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 07hisTestProVolGas_0075573323doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 08hisPurgeVolLiq_0085573413doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 07hisTestProVolLiq_0075573324doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 08hisPurgeVolWtr_0085573414doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 07hisTestProVolWtr_0075573325doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 08hisTestStartTs_0085573415ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 08hisTestEndTs_0085573416ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 08hisTestTimeElapsed_0085573417doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 08hisTestEventCount_0085573418i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 09hisWellCfgOnTest_0095573508i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 08hisTesAlarmCount_0085573419i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 09hisTestId_0095573509i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 09hisAssetId_0095573526i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 08hisTestVolGas_0085573420doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 09hisPurgeStartTs_0095573510ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 08hisTestVolLiq_0085573421doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 09hisPurgeTimeElapsed_0095573511doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 08hisTestVolWtr_0085573422doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 09hisPurgeVolGas_0095573512doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 08hisTestProVolGas_0085573423doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 09hisPurgeVolLiq_0095573513doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 08hisTestProVolLiq_0085573424doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 09hisPurgeVolWtr_0095573514doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 08hisTestProVolWtr_0085573425doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 09hisTestStartTs_0095573515ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 09hisTestEndTs_0095573516ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 09hisTestTimeElapsed_0095573517doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 09hisTestEventCount_0095573518i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Well On Test Number 10hisWellCfgOnTest_0105573608i16iThe numeric identifier of the well test configuration for this well test.
History Alarm Count 09hisTesAlarmCount_0095573519i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Test ID 10hisTestId_0105573609i32iThe unique ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers in the 'User Batch ID' field. This allows the various records to be easily tied together.
History Asset ID 10hisAssetId_0105573626i32iThe configured Asset ID for this well test. This ID appears in the output record for the well test app as well in the output records of the flow computers. This allows the various records to be easily tied together.
History Volume Gas 09hisTestVolGas_0095573520doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Purge Start Time UTC 10hisPurgeStartTs_0105573610ui32i4:unixSeconds;4:unixSeconds; The time at which the 'Purge' state was entered for this well test.
History Volume Liquid 09hisTestVolLiq_0095573521doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Purge Elapsed Time 10hisPurgeTimeElapsed_0105573611doublei640:seconds;640:seconds; 642:minutes; 643:hours; The amount of time spent in the 'Purge' state for this well test.
History Volume Water 09hisTestVolWtr_0095573522doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Purge Volume Gas 10hisPurgeVolGas_0105573612doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Gas 09hisTestProVolGas_0095573523doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Purge Volume Liquid 10hisPurgeVolLiq_0105573613doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid that has passed through the system while in the 'Purge' state for this well test.
History Prorated Volume Liquid 09hisTestProVolLiq_0095573524doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Purge Volume Water 10hisPurgeVolWtr_0105573614doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water that has passed through the system while in the 'Purge' state for this well test
History Prorated Volume Water 09hisTestProVolWtr_0095573525doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.
History Start Time UTC 10hisTestStartTs_0105573615ui32i4:unixSeconds;4:unixSeconds; The start time for this well test.
History End Time UTC 10hisTestEndTs_0105573616ui32i4:unixSeconds;4:unixSeconds; The end time for this well test.
History Elapsed Time 10hisTestTimeElapsed_0105573617doublei640:seconds;640:seconds; 642:minutes; 643:hours; The actual amount of time spent in the 'Test' state for this well test.
History Event Count 10hisTestEventCount_0105573618i16iThe number of flow computer events for all flow runs that occurred during this well test.
History Alarm Count 10hisTesAlarmCount_0105573619i16iThe number of flow computer alarms for all flow runs that occurred during this well test.
History Volume Gas 10hisTestVolGas_0105573620doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test.
History Volume Liquid 10hisTestVolLiq_0105573621doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for the this well test.
History Volume Water 10hisTestVolWtr_0105573622doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test.
History Prorated Volume Gas 10hisTestProVolGas_0105573623doublei1280:e3m3;1280:e3m3; 1281:m3; 1282:ft3; 1283:mmcf; 1284:mcf; The corrected volume of gas for this well test prorated to a 24 hour test.
History Prorated Volume Liquid 10hisTestProVolLiq_0105573624doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of liquid for this well test prorated to a 24 hour test.
History Prorated Volume Water 10hisTestProVolWtr_0105573625doublei1792:lqv_m3;1792:lqv_m3; 1793:lqv_e3m3; 1794:lqv_litre; 1795:lqv_bbl; 1796:lqv_gal; 1797:lqv_ft3; The corrected volume of water for this well test prorated to a 24 hour test.

Table 'Well Test History', (wellTestHistory)

This table has 27 values.

Value Display NameValue NameValue IDValue TypeAllowed UnitsNorm UnitsOptionsMax Length
Row IDid33554432i64primaryKey
Batch User IDbatchId33554433i32isIndex
Start Timestamp UTCtestStartTsUtc33554434dtUtcisIndex
End Timestamp UTCtestEndTsUtc33554435dtUtcisIndex; defaultOrderBy
Start Timestamp UTC Unix SecondstestStartTsUtcUnix33554438ui32
End Timestamp UTC Unix SecondstestEndTsUtcUnix33554439ui32
Well Test NumberconfigNum33554440i32isIndex
Asset IDassetId33554441i32isIndex
Descriptiondescription33554442strng64
Metadatametadata33554443strng128
Purge Start Timestamp UTCpurgeStartTsUtc33554444dtUtc
Purge Elapsed TimepurgeElapsedTime33554446dblseconds; minutes; hoursseconds
Purge Volume GaspurgeVolGas33554447dble3m3
Purge Volume LiquidpurgeVolLiquid33554448dbllqv_m3
Purge Volume WaterpurgeVolWater33554449dbllqv_m3
Test Elapsed TimetestElapsedTime33554450dblseconds; minutes; hoursseconds
Event CounteventCount33554451i32
Alarm CountalarmCount33554452i32
Volume GasvolumeGas33554453dble3m3
Volume LiquidvolumeLiquid33554454dbllqv_m3
Volume WatervolumeWater33554455dbllqv_m3
Prorated Volume GasvolumeGasProrates33554456dble3m3
Prorated Volume LiquidvolumeLiquidProrated33554457dbllqv_m3
Prorated Volume WatervolumeWaterProrated33554458dbllqv_m3